요약·해설과 원문, 전문 번역을 서로 분리했습니다. API 이름, symbol, source path는 원문 표기를 사용합니다.
1. 요약·해설
원문의 핵심 논리와 kernel programming 관점의 보충 설명입니다. 아래의 전문 번역과는 별도로 작성했습니다.
Macro와 variant별 lighting
sysfs-driver-hid-roccat-ryos:92-178최대 480-keystroke macro, glow/pro backlight intensity와 Pro 전용 stored·custom per-key lighting, dimness-mode light macro를 정의합니다.
2. 영어 원문 전체
번역 기준이 된 Linux v6.18.37 원문입니다. 줄 번호는 이 버전의 파일 좌표입니다.
원문 전체 펼치기
What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>/control
Date: October 2013
Contact: Stefan Achatz <erazor_de@users.sourceforge.net>
Description: When written, this file lets one select which data from which
profile will be read next. The data has to be 3 bytes long.
This file is writeonly.
Users: http://roccat.sourceforge.net
What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>/profile
Date: October 2013
Contact: Stefan Achatz <erazor_de@users.sourceforge.net>
Description: The mouse can store 5 profiles which can be switched by the
press of a button. profile holds index of actual profile.
This value is persistent, so its value determines the profile
that's active when the device is powered on next time.
When written, the device activates the set profile immediately.
The data has to be 3 bytes long.
The device will reject invalid data.
Users: http://roccat.sourceforge.net
What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>/keys_primary
Date: October 2013
Contact: Stefan Achatz <erazor_de@users.sourceforge.net>
Description: When written, this file lets one set the default of all keys for
a specific profile. Profile index is included in written data.
The data has to be 125 bytes long.
Before reading this file, control has to be written to select
which profile to read.
Users: http://roccat.sourceforge.net
What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>/keys_function
Date: October 2013
Contact: Stefan Achatz <erazor_de@users.sourceforge.net>
Description: When written, this file lets one set the function of the
function keys for a specific profile. Profile index is included
in written data. The data has to be 95 bytes long.
Before reading this file, control has to be written to select
which profile to read.
Users: http://roccat.sourceforge.net
What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>/keys_macro
Date: October 2013
Contact: Stefan Achatz <erazor_de@users.sourceforge.net>
Description: When written, this file lets one set the function of the macro
keys for a specific profile. Profile index is included in
written data. The data has to be 35 bytes long.
Before reading this file, control has to be written to select
which profile to read.
Users: http://roccat.sourceforge.net
What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>/keys_thumbster
Date: October 2013
Contact: Stefan Achatz <erazor_de@users.sourceforge.net>
Description: When written, this file lets one set the function of the
thumbster keys for a specific profile. Profile index is included
in written data. The data has to be 23 bytes long.
Before reading this file, control has to be written to select
which profile to read.
Users: http://roccat.sourceforge.net
What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>/keys_extra
Date: October 2013
Contact: Stefan Achatz <erazor_de@users.sourceforge.net>
Description: When written, this file lets one set the function of the
capslock and function keys for a specific profile. Profile index
is included in written data. The data has to be 8 bytes long.
Before reading this file, control has to be written to select
which profile to read.
Users: http://roccat.sourceforge.net
What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>/keys_easyzone
Date: October 2013
Contact: Stefan Achatz <erazor_de@users.sourceforge.net>
Description: When written, this file lets one set the function of the
easyzone keys for a specific profile. Profile index is included
in written data. The data has to be 294 bytes long.
Before reading this file, control has to be written to select
which profile to read.
Users: http://roccat.sourceforge.net
What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>/key_mask
Date: October 2013
Contact: Stefan Achatz <erazor_de@users.sourceforge.net>
Description: When written, this file lets one deactivate certain keys like
windows and application keys, to prevent accidental presses.
Profile index for which this settings occur is included in
written data. The data has to be 6 bytes long.
Before reading this file, control has to be written to select
which profile to read.
Users: http://roccat.sourceforge.net
What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>/light
Date: October 2013
Contact: Stefan Achatz <erazor_de@users.sourceforge.net>
Description: When written, this file lets one set the backlight intensity for
a specific profile. Profile index is included in written data.
This attribute is only valid for the glow and pro variant.
The data has to be 16 bytes long.
Before reading this file, control has to be written to select
which profile to read.
Users: http://roccat.sourceforge.net
What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>/macro
Date: October 2013
Contact: Stefan Achatz <erazor_de@users.sourceforge.net>
Description: When written, this file lets one store macros with max 480
keystrokes for a specific button for a specific profile.
Button and profile indexes are included in written data.
The data has to be 2002 bytes long.
Before reading this file, control has to be written to select
which profile and key to read.
Users: http://roccat.sourceforge.net
What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>/info
Date: October 2013
Contact: Stefan Achatz <erazor_de@users.sourceforge.net>
Description: When read, this file returns general data like firmware version.
The data is 8 bytes long.
This file is readonly.
Users: http://roccat.sourceforge.net
What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>/reset
Date: October 2013
Contact: Stefan Achatz <erazor_de@users.sourceforge.net>
Description: When written, this file lets one reset the device.
The data has to be 3 bytes long.
This file is writeonly.
Users: http://roccat.sourceforge.net
What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>/talk
Date: October 2013
Contact: Stefan Achatz <erazor_de@users.sourceforge.net>
Description: When written, this file lets one trigger easyshift functionality
from the host.
The data has to be 16 bytes long.
This file is writeonly.
Users: http://roccat.sourceforge.net
What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>/light_control
Date: October 2013
Contact: Stefan Achatz <erazor_de@users.sourceforge.net>
Description: When written, this file lets one switch between stored and custom
light settings.
This attribute is only valid for the pro variant.
The data has to be 8 bytes long.
This file is writeonly.
Users: http://roccat.sourceforge.net
What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>/stored_lights
Date: October 2013
Contact: Stefan Achatz <erazor_de@users.sourceforge.net>
Description: When written, this file lets one set per-key lighting for different
layers.
This attribute is only valid for the pro variant.
The data has to be 1382 bytes long.
Before reading this file, control has to be written to select
which profile to read.
Users: http://roccat.sourceforge.net
What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>/custom_lights
Date: October 2013
Contact: Stefan Achatz <erazor_de@users.sourceforge.net>
Description: When written, this file lets one set the actual per-key lighting.
This attribute is only valid for the pro variant.
The data has to be 20 bytes long.
This file is writeonly.
Users: http://roccat.sourceforge.net
What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>/light_macro
Date: October 2013
Contact: Stefan Achatz <erazor_de@users.sourceforge.net>
Description: When written, this file lets one set a light macro that is looped
whenever the device gets in dimness mode.
This attribute is only valid for the pro variant.
The data has to be 2002 bytes long.
Before reading this file, control has to be written to select
which profile to read.
Users: http://roccat.sourceforge.net
3. 한국어 전문 번역
영어 원문의 문단 순서와 의미를 유지한 전체 번역입니다. 코드, 함수명, symbol과 URL은 원문 표기를 유지합니다.
control과 persistent profile
1-19BASE=/sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>
$BASE/control
$BASE/profile
모든 항목의 Date는 2013년 10월, contact는 Stefan Achatz <erazor_de@users.sourceforge.net>, user는 http://roccat.sourceforge.net다.
| attribute | payload | access | 동작 |
|---|---|---|---|
| control | 3 byte | write-only | 다음 read의 profile과 data 선택 |
| profile | 3 byte | read/write | 현재 profile index와 다음 power-on profile 저장 |
control에 3 byte를 쓰면 다음 read에서 어느 profile의 어떤 data를 가져올지 선택한다.
device는 button으로 전환할 수 있는 profile 다섯 개를 저장한다. profile은 현재 profile index를 담고 persistent하므로 다음 power-on 때 활성화될 profile도 정한다. 3-byte data를 쓰면 설정한 profile을 즉시 활성화하며 invalid data는 device가 거부한다.
Profile별 key map과 key mask
21-90$BASE/keys_primary
$BASE/keys_function
$BASE/keys_macro
$BASE/keys_thumbster
$BASE/keys_extra
$BASE/keys_easyzone
$BASE/key_mask
| attribute | payload | 설정 대상 |
|---|---|---|
| keys_primary | 125 byte | 특정 profile의 모든 primary key 기본 기능 |
| keys_function | 95 byte | function key 기능 |
| keys_macro | 35 byte | macro key 기능 |
| keys_thumbster | 23 byte | thumbster key 기능 |
| keys_extra | 8 byte | Caps Lock과 function key 기능 |
| keys_easyzone | 294 byte | EasyZone key 기능 |
| key_mask | 6 byte | Windows·application key 같은 특정 key 비활성화 |
각 key map attribute에 쓰면 payload 안의 profile index가 지정하는 profile에 해당 key 기능을 설정한다. payload 길이는 표의 고정 크기와 정확히 같아야 한다.
key_mask는 실수로 누르는 것을 막기 위해 Windows key와 application key 같은 특정 key를 비활성화한다. 적용 profile index가 6-byte data에 포함된다.
이 일곱 file을 읽기 전에는 control에 써서 읽을 profile을 선택해야 한다.
Profile light, macro와 info
92-120$BASE/light
$BASE/macro
$BASE/info
| attribute | payload | access | 동작 |
|---|---|---|---|
| light | 16 byte | read/write | glow·pro variant의 profile별 backlight intensity |
| macro | 2002 byte | read/write | 특정 profile·button의 최대 480-keystroke macro |
| info | 8 byte | read-only | firmware version 등 일반 device data |
light는 glow와 pro variant에서만 유효하다. 16-byte data에 profile index를 포함해 backlight intensity를 설정한다. 읽기 전에는 control로 profile을 선택해야 한다.
macro에 쓰면 특정 profile의 특정 button에 최대 480 keystroke를 저장한다. 2002-byte data에 button index와 profile index가 포함된다. 읽기 전에는 control로 profile과 key를 모두 선택해야 한다.
info를 읽으면 firmware version 같은 일반 device data 8 byte를 반환한다.
Reset, Talk와 Pro per-key lighting
122-178$BASE/reset
$BASE/talk
$BASE/light_control
$BASE/stored_lights
$BASE/custom_lights
$BASE/light_macro
| attribute | payload | access | variant·동작 |
|---|---|---|---|
| reset | 3 byte | write-only | device reset |
| talk | 16 byte | write-only | host에서 EasyShift trigger |
| light_control | 8 byte | write-only | Pro: stored/custom light 설정 전환 |
| stored_lights | 1382 byte | read/write | Pro: layer별 per-key lighting 저장 |
| custom_lights | 20 byte | write-only | Pro: 현재 per-key lighting 설정 |
| light_macro | 2002 byte | read/write | Pro: dimness mode에서 반복할 light macro |
reset에 3 byte를 쓰면 device를 reset하고 talk에 16 byte를 쓰면 host에서 EasyShift 기능을 trigger한다.
light_control은 Pro variant에서만 유효하며 stored light 설정과 custom light 설정 사이를 전환한다.
stored_lights는 Pro variant에서 layer별 per-key lighting을 1382-byte payload로 설정한다. 읽기 전에는 control로 profile을 선택해야 한다.
custom_lights는 Pro variant의 현재 per-key lighting을 20-byte write-only payload로 즉시 설정한다.
light_macro는 device가 dimness mode에 들어갈 때 반복 실행할 light macro를 2002 byte로 설정한다. Pro variant에서만 유효하며 읽기 전에는 control로 profile을 선택해야 한다.
light_control이 persistent layer data와 즉시 적용하는 custom data 중 어느 source를 사용할지 전환한다.
Persistent profile과 key map